Electrical Engineer
Demonstrated experience with Quality Assurance & Testing.
Demonstrated experience with Operation & Maintenance.
Demonstrated experience with Pre Commissioning & Commissioning.
Demonstrated experience with Vendor/Manufacturer Co-ordination.
Demonstrated experience with Detailed Engineering.
Electrical Engineer open to new opportunities
Directed site execution activities involving installation and commissioning of Furnace 3 Submerged Arc Furnace transformer, 11KV panel, battery charger, control panel, MCC Panel, and cable laying.. Installed and commissioned an additional 3 no.’s motor and starter system in the pump house to support a major furnace 3 load expansion, including 3 Ph Induction motor installation, cable laying termination, IR and functional test.. Executed installation at the KFA New Labor Camp Building of 440 V LV Panel, DB’s, lighting and power layout as per Load Calculation, DG set with ATS.. Started, tested and commissioned a Diesel Generator 415 V, 770 KVA with 630 AMP ATS & 1250 AMP G-MSB, including Cable Laying, Glanding, Termination & Insulation Resistance checks.. Installed Automatic Power Factor Correction Panel (APFC) of 4800 KVAR, 11KV, 3 Ph, 50 Hz with series reactor.. Managed replacement of metal halide lamps with LED fixtures and executed wiring and circuit configurations as per blueprints and layouts; conducted LUX testing.. Performed maintenance on HT Substations 11KV Panel and Auxiliaries.. Planned and prepared preventive and corrective maintenance activities, logs, daily load readings, equipment history cards, and test certificates of electrical equipment.. Planned and coordinated electrical maintenance in the running plant and during shutdown maintenance.. Coordinated maintenance, start-up, commissioning and operation of electrical equipment and substations in the plant area.. Followed electrical working safety rules and regulations.
Performed routine testing of 11KV Switchgear Panel, including Functional test, Power Frequency Test, Primary test using Omicron Kit 100, Secondary Injection test using kit 256/356, and Contact Resistance Check as per schematic drawing.. Performed routine testing of 300/132/11kv Control & Relay Panel, 33KV 45 MVAR Shunt Reactor CRP Panel, and OLTC Panel.. Performed Parallel Operation testing of 4 OLTC 30MVA Panel and 300 MVA 4 OLTC Panel.. Performed routine testing of LV Distribution Panel and MCC Panel.. Performed routine testing of Battery Charger Panel, including measurement of input and output parameters with and without load, setting Boost/Float charging current and voltage parameters, and charging batteries in Float and Boost modes in Auto or Manual mode.. Handled projects for KAHRAMAA, QATAR; MEW/PAHW/KOC/KNPC, KUWAIT; and EWA, BAHRAIN.
Developed and implemented plans and schedules for Maintenance Operations and Annual Turn around with focus on optimum utilization of manpower and material.. Managed troubleshooting and preventive/breakdown maintenance of Electrical Equipment’s/Systems to reduce downtime to minimum.. Undertook regular inspections to prevent accidents and adhere to safety/environmental norms.. Dealt daily with site planner and manager to solve critical issues to avoid line down situations.. Maintained monthly operating reviews, daily log sheets, different registers, and other records.. Liaised with other departments and supervised ongoing works at yard and line.. Maintained substation equipment by issuing work permits under safety guidelines for troubleshooting and condition monitoring.. Maintained power transformers of 100 MVA & 160 MVA for voltage class of 220/66KV, circuit breakers (SF6, VCB), CTs, PTs, LA, Battery Chargers, Isolators, and other equipment.. Operated and maintained control and relay panels, LV panel, and DB.. Transferred load to another outgoing feeder panel as required.. Monitored SCADA from the control room.